> For the complete documentation index, see [llms.txt](https://help.clabassistant.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.clabassistant.com/manage-a-project/reference-projects.md).

# Start from a Reference Project

Use an existing project as the starting point for a new design. The new project has its own name, code, tags, and version history.

## Copy a project's configuration

1. On the Dashboard, click **+** to add a project.
2. Enter the new project's details and select **From reference project**.
3. Search for and select the configured source project in your workspace.
4. Create the project and review its measurements, piece options, and grading.

For an existing empty project, open **Project Settings** and choose **Start from Reference Project**. This is available before an anatomical set and Pattern Type have been assigned.

The new project keeps the source's anatomical set, Pattern Type, entered measurements, configuration, and any existing template association. It uses the shared anatomical set's current measurements.

Where point editing is available, saved point adjustments and piece placement are also copied. Review the geometry in the new project before generating files.

A shared size chart remains shared. A local size chart is copied for the new project, including its grading rules, so local changes do not affect the source chart. The new project starts unlocked and does not inherit the source's saved versions.

## Use a project as a saved design reference

Where **Use as reference** is available for the workspace and Pattern Type:

1. Choose **Use as reference** on an active Dashboard project card, or **Project Settings → New from this pattern…** in the editor.
2. Wait for the project to finish preparing if needed.
3. Enter the new project's name, optional code, and tags. **From project** is already selected, with the source fixed to the project you chose.
4. Create the project and review the result.

This captures the source's current measurement customizations as a saved design reference, including adjustments from an existing template. It also carries over the project's configuration and assigned grading, following the chart behavior described above.

The resulting project shows a **reference** badge beside its name. Open it to inspect the source details. If a source-project link is available, it opens that project's current state; later edits to the source do not rewrite the saved reference.

A saved reference is separate from the shared Pattern Template catalog. Use [Save a project as a template](https://help.clabassistant.com/manage-a-project/pattern-templates.md#save-a-project-as-a-template) when you want a reusable catalog entry that the team can manage.

## Disconnect a saved design reference

Open the **reference** badge details and use the disconnect button. Optionally select **Keep the measurements inherited from this reference** to turn the current inherited inputs into editable project values. Each linked saved version keeps its own corresponding inputs. Review the warning, select **Confirm reference disconnection**, and confirm.

Without the keep option, existing user-entered values remain but the reference’s defaults and adjustments are removed. Configuration and grading remain. Standard Pattern Type calculations apply after disconnection, so review the preview; keeping inputs does not freeze geometry or preserve the reference’s adaptation rules. Other projects using the reference are unaffected.

## Review shared settings

The new project is independent, but shared anatomical sets, directly assigned shared size charts, and existing catalog template associations can still affect multiple projects. Check these before editing shared data, and use a local chart when grading changes should apply only to the new project.
